/gras/analysis/common/general/


Sub-directories :


Commands :


bookHistos [truefalse]

Decides if histograms are created or not for the module

Available at all Geant4 states.

Parameters
truefalse type b Omittable : default value = 1


bookHistosVsPrimary [truefalse]

Decides if histograms versus primary kinetic energy are created or not for the module

Available at all Geant4 states.

Parameters
truefalse type b Omittable : default value = 0


bookHistosAdvanced [truefalse]

Decides if more advanced histograms are created or not for the module

Available at all Geant4 states.

Parameters
truefalse type b Omittable : default value = 0


bookTuples [truefalse]

Decides if histograms are created or not for the module

Available at all Geant4 states.

Parameters
truefalse type b Omittable : default value = 1


addVolume [volume] [copyno]

Add a physical volume to the module

Available at all Geant4 states.

Parameters
volume type s
copyno type i Omittable : default value = -1


addVolumeInterface [volume] [volume] [copyno] [copyno]

Add to the module an interface between 2 physical volumes

Available at all Geant4 states.

Parameters
volume type s
volume type s
copyno type i Omittable : default value = -1
copyno type i Omittable : default value = -1


setInterfaceSurfaceArea [area] [Unit]

Set the interface surface area for the results normalisation

Range : area > 0.

Available Geant4 state(s) : PreInit Idle

Parameters
area type d
Unit type s Parameter candidates : mm2 cm2 m2


autoInterfaceSurfaceArea [truefalse]

true / false
If true, the interface surface area is automatically computed as the area of the surface of the 2nd volume in the inserted interface

Available at all Geant4 states.

Parameters
truefalse type b Omittable : default value = 1


setVolumeSurfaceArea [area] [Unit]

Set the volume surface area for the results normalisation

Range : area > 0.

Available Geant4 state(s) : PreInit Idle

Parameters
area type d
Unit type s Parameter candidates : mm2 cm2 m2


autoVolumeSurfaceArea [truefalse]

true / false
If true, the volume surface area is automatically computed for the inserted volume

Available at all Geant4 states.

Parameters
truefalse type b Omittable : default value = 1


setVolume [vol] [Unit]

Set the volume for the results normalisation

Range : vol > 0.

Available Geant4 state(s) : PreInit Idle

Parameters
vol type d
Unit type s Parameter candidates : mm3 cm3 m3


autoVolume [truefalse]

true / false
If true, the volume is automatically computed as the sum of the volume of all inserted volumes

Available at all Geant4 states.

Parameters
truefalse type b Omittable : default value = 1


setUnit [truefalse]

Set the unit for the output

Available at all Geant4 states.

Parameters
truefalse type s


listUnits

List available units for the output

Available at all Geant4 states.


printResults

List available units for the output

Available at all Geant4 states.


verbose []

Set verbose level

Available at all Geant4 states.

Parameters
type i


setVisTrigger [truefalse]

Decides if the module triggers the visualisation of the event

Available at all Geant4 states.

Parameters
truefalse type b Omittable : default value = 1


initialise

Initialisation of all analysis modules

Available Geant4 state(s) : Idle PreInit


detailedTuples [truefalse]

true / false
If true, more variables are recorded into the tuples

Available at all Geant4 states.

Parameters
truefalse type b Omittable : default value = 1